An equalization charge is a controlled over-charge of the battery set to allow the electrolyte to mix properly and to promote equal cell voltages and specific gravity readings.

  1. Perform all periodic maintenance checks(fluid level, clean batteries, good terminal connections, proper charging).
  2. Make sure that the car was charged the night before and that the charger has cycled off.
  3. Unplug the charger from the car.
  4. Inspect the DC plug of the charger and the receptacle of the car for any damage.
  5. Plug the charger back in to the car to restart the charger.
  6. Allow the charger to run until it cycles off.
  7. Unplug the charger and re-plug immediately after the previous charger cycle.
  8. Repeat for three consecutive charge cycles.
  9. Allow batteries to cool.
  10. Inspect and / or correct the electrolyte level in all battery cells.
  11. Return the car to service.

 

 

 